UD-02 Air and Power Supply Sizing Check
Work out what a UD-02 installation asks of your compressed air and your electrical supply before you request a quotation. The machine constants below are the published UD-02 figures; everything else is yours to set.
Your installation
Results appear here.
Machine constants used
| Constant | Value | Where it comes from |
|---|---|---|
| Compressed air per line | 0.2 m³/min at 0.6 MPa or above | UD-02 published specification |
| Connected load per line | 12 kW | UD-02 published specification |
| Supply | Three-phase 380 V | UD-02 published specification |
Power factor is a planning assumption you set, not a UD-02 specification. The breaker figure applies the common planning rule of 1.25 times the calculated running current and then rounds up to the next standard frame size; confirm the final selection against your local electrical code and your installer. Air margin covers pipe losses and simultaneous demand, and is also yours to set.